Get a consultation

Samum-12 vortex burner

Samum 12 is a modernized series of vortex burners, designed on the basis of the PV series burners, taking into account extensive experience in their operation. SAMUM 12 series burners with a capacity of 2-6 MW (with a capacity step of 2 MW) are manufactured in a vertical configuration with a conical grate and one high-pressure fan. The minimum working length of the feed screw (without a gear motor) is 1.2 m. This burner is universal and can operate on various units: heat generators, steam boilers, etc.

Areas of use:  Thermal power generation, industry, agriculture, construction industry, waste processing, autonomous energy systems.

Specialist consultation
Thermal capacity, MW 2.0 4.0 6.0
Adjustment range, % 40…120 40…120 40…120
Fuel consumption, kg/h, at Qnp= 15.5 MJ/kg (for sunflower husks) 460 930 1,390
at Qnp≈ 19.0 MJ/kg (for wood pellets) 380 760 1,140
at Qnp≈ 17.0 MJ/kg (for cleaning waste pellets) 420 850 1,270
at Qnp≈ 13.0 MJ/kg (for rice husk) 550 1,110 1,660
at Qnp≈ 12.0 MJ/kg (for cod Wp=30%) 590 1,180 1,770
Air consumption for combustion, m³/h, (for sunflower husk with excess air coefficient α=2) 3,700 7,500 11,100
Volume of combustion products, m³/h, (at excess air coefficient α=2, torch temperature t≈800°C) 16,800 34,100 50,900
Thermal stress of the section, kW/m² 1,768 3,537 5,305
Volume thermal stress, kW/m³ 974 1,970 2,944
Vacuum in the center of the chamber, Pa 30…90 30…90 30…90
Fan brand BP 129-28; No. 5, ex. 1, k=1.0; 5.4 kPa, 3600 rpm, 15 kW BP 129-28; No. 6.3, test. 1, k=0.95; 5.3 kPa, 2940 rpm, 22 kW 1x BP 129-28; No. 10, test 1, k=1.05; 5.2 kPa, 1475 rpm, 30 kW
Electricity consumption, kW 15.0 22.0 30.0
Implementation Vertical Vertical Vertical
Internal diameter of combustion chamber, mm 1,200 1,200 1,200
Diameter of the output nozzle in the light, mm 600 600 600
Height (without hopper), mm 2,050 2,050 2,050
Width (without fans), mm 1,700 1,700 1,700
Length (without feed screw), mm 2,100 2,100 2,100
Assembled weight, kg 4,500 4,500 4,500

Go back

Go back

    Consultation with a specialist

    Manufacturing type
    Coolant
    Fuel
    Power, Steam capacity, mW t/hour
    1
    5
    10
    15
    20
    25
    30